KRYLON DIV OF SHERWIN WILLIAMS -- CWA1159 CLEAR QUICK DRY LACQUER -- 8010-00F057052
===================== Product Identification ===================== Product ID:CWA1159 CLEAR QUICK DRY LACQUER MSDS Date:11/01/1995 FSC:8010 NIIN:00F057052 Status Code:A === Responsible Party === Company Name:KRYLON DIV OF SHERWIN WILLIAMS Address:31500 SOLON RD City:SOLON State:OH ZIP:44139-3908 Country:US Info Phone Num:216-292-7400/800-832-2541 Emergency Phone Num:216-292-7400/800-832-2541 CAGE:KRYLO === Contractor Identification === Company Name:KRYLON DIV OF SHERWIN WILLIAMS Address:6830 COCHRAN RD City:SOLON State:OH ZIP:44139-3908 Country:US Phone:216-292-7400/800-832-2541 CAGE:KRYLO ============= Composition/Information on Ingredients ============= Ingred Name:PROPANE (DIMETHYLMETHANE) *98-3* CAS:74-98-6 RTECS #:TX2275000 Fraction by Wt: 16% Other REC Limits:1800 MG/CUM OSHA PEL:1000 PPM ACGIH TLV:SIMPLE ASPHYXIANT Ingred Name:LIGHT ALIPHATIC NAPHTHA, VM & P NAPHTHA, LACOLENE *98-3* CAS:64742-89-8 Fraction by Wt: 2% OSHA PEL:300 PPM ACGIH TLV:300 PPM Ingred Name:ETHYL BENZENE *98-3* CAS:100-41-4 RTECS #:DA0700000 Fraction by Wt: 1% Other REC Limits:100 PPM OSHA PEL:435 MG/CUM ACGIH TLV:434 MG/CUM EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:XYLENE, DIMETHYLBENZENE, XYLOL (IARC - GROUP 3) *98-3* CAS:1330-20-7 RTECS #:ZE2100000 Fraction by Wt: 6% Other REC Limits:100 PPM OSHA PEL:100 PPM ACGIH TLV:100 PPM, SKIN EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:ISOPROPANOL (ISOPROPYL ALCOHOL), 2-PROPANOL, DIMETHYL CARBINOL (IARC-GROUP 3) *98-3* CAS:67-63-0 RTECS #:NT8050000 Fraction by Wt: 3% Other REC Limits:400 PPM OSHA PEL:400 PPM ACGIH TLV:400 PPM Ingred Name:ACETONE; DIMETHYL KETONE; 2-PROPANONE *98-3* CAS:67-64-1 RTECS #:AL3150000 Fraction by Wt: 43% OSHA PEL:2400 MG/CUM ACGIH TLV:750 PPM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:METHYL ETHYL KETONE, 2-BUTANONE *98-3* CAS:78-93-3 RTECS #:EL6475000 Fraction by Wt: 4% Other REC Limits:590 MG/CUM OSHA PEL:200 PPM ACGIH TLV:590 MG/CUM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:HEXONE, METHYL ISOBUTYL KETONE (MIBK), 4-METHYL-2-PENTANONE *98-3* CAS:108-10-1 RTECS #:SA9275000 Fraction by Wt: 4% Other REC Limits:50 PPM OSHA PEL:410 MG/CUM ACGIH TLV:205 MG/CUM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:ISOPROPYL ACETATE *98-3* CAS:108-21-4 RTECS #:AI4930000 Fraction by Wt: 4% Other REC Limits:250 PPM OSHA PEL:250 PPM ACGIH TLV:1040 MG/CUM Ingred Name:ETHYL 3-ETHOXYPROPIONATE, PROPANOIC ACID, 3-ETHOXY-, ETHYL ESTER *98-3* CAS:763-69-9 RTECS #:UF3325000 Fraction by Wt: 6% Ingred Name:BUTYL ACETATE (N-BUTYL ACETATE) *98-3* CAS:123-86-4 RTECS #:AF7350000 Fraction by Wt: 2% Other REC Limits:150 PPM OSHA PEL:710 MG/CUM ACGIH TLV:713 MG/CUM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:AMYL ACETATE CAS:628-63-7 RTECS #:AJ1925000 Fraction by Wt: 4% Other REC Limits:530 PPM OSHA PEL:100 PPM ACGIH TLV:100 PPM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:VOLATILE ORGANIC CONTENT: 92%/WT, PER BAAQMD RULE 49 RTECS #:9999999VO ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:INHALATION: IRRITATION OF EYES, SKIN & RESPIRATORY SYSTEM. NERVOUS SYSTEM DEPRESSION/POSSIBLY DEATH. PROLONGED OVEREXPOSURE TO SOLVENTS MAY CAUSE ADVERSE EFFECTS TO THE LIVER, URINARY, CARDIOVASCULAR & REPRODUCTIVE SYSTEMS. REPEATED/PROLONGED OVEREXPOSURE TO SOLVENTS MAY CAUSE PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE. Explanation of Carcinogenicity:NONE Effects of Overexposure:IRRITATION, UNCONSCIOUSNESS, HEADACHE, DIZZINESS, NAUSEA, LOSS OF COORDINATION, REDNESS, ITCHING, BURNING SENSATION Medical Cond Aggravated by Exposure:NONE ======================= First Aid Measures ======================= First Aid:INHALATION: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM & QUIET. SKIN: WASH THOROUGHLY W/SOAP & WATER. EYES: FLUSH W/LARGE AMOUNTS OF WATER FOR 15 MINS. OBTAIN MEDICAL ATTENTION IN ALL CASES. ===================== Fire Fighting Measures ===================== Flash Point Method:PMCC Flash Point:<0F Lower Limits:0.7 Upper Limits:12.8 Extinguishing Media:CO2, DRY CHEMICAL, FOAM Fire Fighting Procedures:USE FULL PROTECTIVE EQUIPMENT W/SCBA. WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZZLES ARE PREFERRED. WATER MAY BE USED TO COOL CLOSED CONTAINERS. Unusual Fire/Explosion Hazard:ISOLATE FROM IGNITION SOURCES/HOT SURFACES. CLOSED CONTAINERS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT. VAPORS WILL ACCUMULATE READILY & MAY IGNITE EXPLOSIVELY. ================== Accidental Release Measures ================== Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE & REMOVE W/INERT ABSORBENT. DON'T INCINERATE CONTAINERS. ====================== Handling and Storage ====================== Handling and Storage Precautions:KEEP FROM IGNITION SOURCES. USE APPROVED BONDING/GROUNDING PROCEDURE. DURING USE/UNTIL ALL VAPORS ARE GONE, VENTILATE AREA. AVOID BREATHING VAPORS. Other Precautions:KEEP OUT OF REACH OF CHILDREN. DON'T TAKE INTERNALLY. DON'T PUNCTURE/INCINERATE/EXPOSE TO TEMPS >120F. HEAT FROM SUNLIGHT, RADIATORS, STOVES, HOT WATER/OTHER HEAT SOURCES MAY CAUSE CONTAINER TO BURST. AVOID CONTACT W/SKIN & EYES. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:IF EXPOSURE CANNOT BE CONTROLLED1 Evaporation Rate & Reference:FASTER THAN ETHER ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES Stability Condition to Avoid:EXTREME HEAT, ELECTRICAL EQUIPMENT, SPARKS, OPEN FLAME, HOT SURFACES Hazardous Decomposition Products:BY FIRE: CO2, CO ==================== Disposal Considerations ==================== Waste Disposal Methods:WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINE THE APPLICABLE EPA HAZARDOUS WASTE NUMBERS. WASTE CONTAINING METHYL ETHYL KETONE MAY REQUIRE TESTING FOR EXTRACTABILITY. DISPOSE OF IAW/LOCAL, STATE & FEDERAL REGULATIONS. DEPRESSURIZE CONTAINER. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.